Product Description
last update: September 24, 2012
Ratings
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC |
5 5 |
1.5 1 |
0.7 0.5 |
3 3 |
2 1.5 |
1 0.8 |
||
12 VDC 24 VDC 125 VDC 250 VDC |
5 5 |
3 3 |
4 4 |
3 3 |
||||
0.4 0.4 |
0.2 0.2 |
– | – | – |
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush current | NC | 24 A max. |
---|---|---|
NO | 12 A max. |
Characteristics
Degree of protection | IP65 | |
---|---|---|
Durability * | Mechanical | 10,000,000 operations min. (under rated conditions) |
Electrical | See the following Electrical Durability. | |
Operating speed | 5 mm/s to 0.5 m/s | |
Operating frequency | Mechanical | 120 operations/min |
Electrical | 30 operations/min | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 25 mΩ max. (initial value) | |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity | |
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground | ||
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part | ||
Rated frequency | 50/60 Hz | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance | Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. | |
Ambient operating temperature | -5°C to +65°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 130 to 190 g |
Note: 1. The above figures are initial values.
2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales
representative.
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed information on other operating environments.
2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales
representative.
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed information on other operating environments.
Reviews